DH100 Series

Share:

Description

DH100 Series high temperature dry bath incubator controlled by microcomputer, use high purity aluminum material as a heat conduction medium instead of the conditional water bath device. which is easy to use, wide temperature range, high precision and etc. It can be widely used in the sample preservation, reaction of DNA amplification, electrophoresis, degeneration, solidification and other kinds of serum biochemical sample thermostatic incubation process.

 

Features:

1. Real-time temperature display, the countdown display.

2. Convenient block replacement, easy to clean and disinfect.

3. Automatic fault detection and alarm function

4. Built-in over temperature protection device

5. Temperature deviation calibration function

E-mail : sales@ruiwell.com / info@ruiwell.com

Product modelParameters
Product model DH100-1 DH100-2 DH100-4
Temperature range RT.+5°C~160°C
RT.+5°C~160°C RT.+5°C~130°C
Temp accuracy ±0.5℃(@40℃)
Temp accuracy  ±1℃(@120℃)
 Temp uniformity  ±0.5℃ 
 Display accuracy  0.1℃ 
 Time range  1-99h59min/∞ 
 Heating time  ≤15min(from 25℃ to 160℃) ≤15min(from 25℃ to 160℃)   ≤20min(from25℃ to 130℃)
 Block quantity  1 2  4 
 Max power  300W  500W  600W
 Voltage  AC220V or AC110V, 50/60Hz
 Size  260 x 220 x 100mm  260 x 220 x 100mm  360 x 220 x 100mm
Weight 5.0kg 5.5Kg 8.0kg
    Optional ModulesHole Diameter Number of HolesRemarks 
    MD01 6mm 48 Hole depth 47mm
    MD02 7mm 48 Hole depth 47mm
    MD03 10mm 24 Hole depth 47mm
    MD04 12mm 24 Hole depth 47mm
    MD05 13mm 24 Hole depth 47mm
    MD06 15mm 16 Hole depth 47mm
    MD07 16mm 16 Hole depth 47mm
    MD08 19mm 12 Hole depth 47mm
    MD09 20mm 12 Hole depth 47mm
    MD10 26mm 8 Hole depth 47mm
    MD11 28mm 4 Hole depth 47mm
    MD12 40mm 3 Hole depth 47mm
    MD13 0.2ml (centrifuge tubes) 48 Standard centrifuge tubes
    MD14 0.5ml (centrifuge tubes) 48 Standard centrifuge tubes
    MD15 1.5ml (centrifuge tubes) 24 Standard centrifuge tubes
    MD16 2.0ml (centrifuge tubes) 24 Standard centrifuge tubes
    MD17 0.2ml (PCR tubes) 96 Not applicable for DH100-1
    MD18 0.2ml (ELISA plates) 96 Not applicable for DH100-1
    Customized Module Provided by customer    
    Note: The modules MD17 and MD18 are twice the size of the standard module, so selecting MD17 or MD18 means that the number of selected modules is 2.

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    MD01 to MD18 Modules

Related products